Requirement
• A SINAMICS S120 Control Unit (or a SIMATIC Drive Controller) has been inserted in the device
configuration.
Restriction
• When using a CU310-2 PN, DRIVE-CLiQ Hub Modules inserted in the device configuration are
not automatically wired via DRIVE-CLiQ.
Procedure
Proceed as follows to insert a DRIVE-CLiQ Hub Module in your device configuration:
1. Open the "DRIVE-CLiQ Hub Modules" entry in the hardware catalog.
2. Drag the "DRIVE-CLiQ HUB Module DMx20" Hub Module and drop it into the device
configuration.
The component is automatically interconnected with the Control Unit via DRIVE-CLiQ.
Further information on the inserted Hub Module is provided in the inspector window.
Note
No automatic wiring
With an S120 drive system with a CU310-2 PN, the DRIVE-CLiQ Hub Module is not
automatically wired via DRIVE-CLiQ. In this case, you must create the DRIVE-CLiQ wiring
manually.
• Click on a DRIVE-CLiQ interface of the Hub Module and establish a DRIVE-CLiQ connection
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2
to the target port of the required component (e.g. the CU).