Creating a DRIVE-CLiQ connection
To create a DRIVE-CLiQ connection between two DRIVE-CLiQ ports, proceed as follows.
1. Left-click the output port and keep the mouse button pressed.
2. Drag the line displayed to the target port.
A DRIVE-CLiQ connection is established between the ports and is displayed as a blue line.
5.3.5.6

Making detailed settings

Overview
The following detailed settings can be made during commissioning:
• Drive unit line supply voltage for all types of infeed units
• Parameterization of a line filter when using an Active Line Module (ALM)
Important notes
Observe the following information before you make the detailed settings for the infeed unit that
is used.
Note
Use of an Active Line Module
Following automatic commissioning, the appropriate filter for the matching Active Interface
Module (AIM) is pre-selected as the line filter. If the drive line-up is set up differently, then the line
filter type must be adjusted.
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2
Commissioning
5.3 Creating a project offline
119