Manual Rebuild

When a user applies forced-manual rebuild, the controller will first
check whether there is any Local Spare Drive assigned to this logical
drive. If yes, it will automatically start to rebuild.
If there is no Local Spare Drive available, the controller will search for
a Global Spare Drive.
automatically rebuild the logical drive.
User applies
forced-manual
rebuild
Chapter 3 Functional Descriptions
If there is a Global Spare Drive, it will
Any
Yes
Local Spare Drive
assigned to this
logical drive?
No
Any
Yes
Global Spare Drive
assigned to this
logical drive?
No
Yes
Has the failed drive
been replaced?
No
Wait for
manual rebuild
Rebuild using the
Local Spare Drive
Rebuild using the
Global Spare Drive
Rebuild using the
replaced drive