Acer AcerAltos 3102RS User Manual page 149

Ultra-scsi to ultra-scsi raid controller
Table of Contents

Advertisement

Item
Global
Status
INITING
ON-LINE
REBUILD
STAND-BY
NEW DRV
USED DRV
ABSENT
MISSING
SB-MISS
Vendor
The vendor and product model information of the drive.
and
Product
ID
Chapter 8 RS-232C Terminal Interface
Description
logical drive x.
If the Status column showed "STAND-BY",
the SCSI drive is a Local Spare Drive of
logical drive x.
The SCSI drive is a Global Spare Drive.
Processing initialization.
The drive is in good condition.
Processing Rebuild.
Local Spare Drive or Global Spare Drive.
The Local Spare Drive's LG_DRV column
will show the logical drive number. The
Global Spare Drive's LG_DRV column will
show "Global".
The new drive has not been configured to
any logical drive or as a spare drive.
The used drive has not been configured to
any logical drive or as a spare drive.
BAD
Failed drive.
Drive does not exist.
Drive once exist, but is missing now.
Spare drive missing.
131