1. Edit the GUD variable definitions
DEF CHAN REAL CLC_DISTANCE[3] ; Array of real, 3 elements
DEF CHAN REAL CLC_VOLTAGE[3] ; Array of real, 3 elements
M30
2. Save the file and close the editor.
3. Activate the SGUD.DEF file.
The GUD variables for clearance control are now displayed under:
Operating area switchover > Parameters > User data > Channel user data
SINUMERIK Operate
Proceed as follows to create and display the GUD variables for SINUMERIK Operate.
1. Setting the password
Enter the password for protection level 1: (machine manufacturer).
2. If no SGUD.DEF file is yet available:
Operating area switchover > Commissioning > System data > Open NC data directory: Set
cursor to definitions > New...
● Name: SGUD
● Type: DEF
Confirm with OK.
This opens the file in the editor.
1. Edit the GUD variable definitions
DEF CHAN REAL CLC_DISTANCE[3] ; Array of real, 3 elements
DEF CHAN REAL CLC_VOLTAGE[3] ; Array of real, 3 elements
M30
2. Save the file and close the editor.
3. Activate the SGUD.DEF file.
The GUD variables for clearance control are now displayed under:
Operating area switchover > Parameters > User variables > GUD channel
SINUMERIK NCK
The new GUD variables, which are already being displayed, will only be detected by the
clearance control function and supplied with up-to-date values following an NCK POWER ON
RESET.
Note
Once the GUD variables have been created, an NCK POWER ON RESET must be carried
out in order for the clearance control function to update the GUD variables.