TE01: Installation and activation of loadable compile cycles

13.2 Interface version compatibility

13.1.3

Loading a compile cycle from an external computer with WinSCP3

Precondition
To transfer a compile cycle to the control, the following requirements must be met:
● The external computer (programming device / PC) which the compile cycle is loaded onto
is linked to the PCU via a network (TCP / IP).
● The program "WinSCP3" is installed on the external computer.
● The host name or the IP address of the PCU is known.
● The user name and the password to log onto the PCU are known.
Execution
Perform the following operation to load a compile cycle from an external computer into the
NCK:
1. Start the "WinSCP3" program on the external computer (programming device / PC)
2. Establish a connection to the PCU by selecting an appropriate profile or by entering the
host name or IP address, the user name and the password.
3. Copy the compile cycle from the external computer into the following directory on the PCU:
/card/oem/sinumerik/data/cc
The file name of the compile cycle should have any capital letters in the directory of the
PCU.
4. Initiate an NCK reset.
13.2
Interface version compatibility
The compile cycle and the NCK system software communicate via a SINUMERIK-specific
interface. The interface version used by the loaded compile cycle must be compatible with the
interface version of the NCK system software.
552
Function Manual, 01/2015, 6FC5397-2BP40-5BA2