Download Print this page

Kenwood NX-5000 Series Function Reference page 128

Dmr func
Hide thumbs Also See for NX-5000 Series:

Advertisement

2 COMMUNICATIONS IN AN EMERGENCY
2.8 Placing the Transceiver in Emergency Mode Using the Lone Worker Function
Lone Worker Type can be configured using KPG-D1/ D1N depending on the usage of the transceiver. The transceiver
behavior varies as below depending on the configuration in Lone Worker Type:
Transceiver Behavior
Toggling Lone Worker Mode between enabled
and disabled when a channel is changed
Toggling the Lone Worker Mode between
enabled and disabled by a user pressing the
Lone Worker key
Retaining the status of Lone Worker Mode,
either enabled or disabled, in the transceiver
Transmitting and receiving by operating the
transceiver in the same manner as normal mode
Yes: Available
No: Unavailable
Configuration using KPG-D1/ D1N
Configuring Lone Worker Type (
Lone Worker Interval
Lone Worker Interval is the interval time from when the transceiver enters Lone Worker Mode until the Lone Worker Tone
(2 beeps) sounds from the transceiver.
If no key is pressed after the transceiver enters Lone Worker Mode and then Lone Worker Interval is activated, the Lone
Worker Tone (2 beeps) sounds from the transceiver when the time configured in Lone Worker Interval elapses. For the time
configured in Duration of Lone Worker Tone, the Lone Worker Tone (2 beeps) sounds from the transceiver.
If any key is pressed before the time configured in Lone Worker Interval elapses, Lone Worker Interval is reset and then
restarts counting down from the beginning. Also, if the Lone Worker key is pressed before the time configured in Lone
Worker Interval elapses, Lone Worker Mode becomes disabled and then the transceiver reverts to the normal mode.
Configuration using KPG-D1/ D1N
Configuring Lone Worker Interval (
DMR FUNC (K, F)/Ver 2.20
Table 2-10 Lone Worker Type
Configuration in Lone Worker Type
Normal
No
Yes
Yes
Yes
Transceiver Settings > Emergency > Emergency Information > Lone Worker)
Transceiver Settings > Emergency > Emergency Information > Lone Worker)
Transmit/Receive
Inhibit
No
Yes
Yes
No
CONTENTS
INDEX
Preset
Yes
Yes
No
Yes
111

Advertisement

loading

This manual is also suitable for: