Table 3- 13
Technical data for Active Interface Modules, 500 V ... 690 V 3 AC
Article number
Suitable for Active Line Module
Rated power of
Active Line Module
Rated current
Supply voltages
- Line voltage
- Line frequency
- Electronics power supply
DC link capacitance
of the drive line-up, max.
Electronics current consumption (24 V DC)
Bypass contactor
1)
Max. coolant temperature
- without derating
- with derating
Rated flow rate
for water with 70 kPa pressure drop
Sound pressure level
L
(1 m) at 50/60 Hz
pA
Frame size
Filter reactor
Article number
Cooling method
Power loss, max.
2)
- At 50 Hz 690 V
- At 60 Hz 575 V
- Dissipated to the ambient air
Liquid volumes
- Integrated reactor cooler
- Hoses supplied
Rated flow rate
for water with 70 kPa pressure drop
Coolant connections
Return and connection to filter module
Tightening torque for coolant connections
Line/load connection
U1, V1, W1 / U2, V2, W2
PE connection
Water-cooled chassis power units for common cooling circuits
Manual, 08/2017, 6SL3097-4AM10-0BP0
6SL3305–
7TG41–0AA7
6SL3335-
7TG41-0AA7
kW
1100
7TG38-1AA7
900
A
1025
V
3 AC 500 –10% (-15% < 1 min) ... 3 AC 690 +10%
ACrms
Hz
V
DC
µF
153600
A
0.17
3WL1212-
4BB34-4AN2-Z
Z=C22
3)
°C
45
°C
50
l/min
10
dB(A)
71 / 71
JIL
6SL3005-
0DG41-3AA7
Water cooling system with integrated heat exchanger manufac-
kW
6.2
kW
6.2
kW
0.6
dm³
0.6
dm³/m
0.285
l/min
10
Nm
6
Flat connection
for M12 screw
M10 bolts
Line-side power components
3.2 Active Interface Modules
7TG41–3AA7
7TG41–6AA7
7TG41-3AA7
7TG41-6AA7
1400
1700
1270
1560
47 ... 63 Hz
24 (20.4 ... 28.8)
153600
210000
0.17
0.17
3WL1216-
3WL1216-
4BB34-4AN2-Z
4BB34-4AN2-Z
Z=C22
Z=C22
3)
45
45
50
50
10
16
71 / 71
71 / 71
JIL
JIL
0DG41-3AA7
0DG41-6AA7
tured out of a copper-nickel alloy
9.3
11
9.3
11
0.95
1.15
0.6
0.6
0.285
0.285
10
10
Pipe thread ISO 228 - G 3/4 B
(external thread 3/4", flat-sealing)
6
6
Flat connection
Flat connection
for M12 screw
for M12 screw
M10 bolts
M10 bolts
3)
69

Advertisement