Line/Load Connection; X9 Terminal Strip - Siemens SINAMICS S120 Equipment Manual

Water-cooled chassis power units for common cooling circuits
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Active Line Modules
5.3 Interface description
5.3.3

Line/load connection

Table 5- 2
Line/load connection of the Active Line Module
Terminals
U1, V1, W1
3 AC power input
DCP, DCN
DC power output
PE connection
Dimensions for connecting alternative cable lugs, see "cable lugs" in the appendix.
1)
5.3.4

X9 terminal strip

Table 5- 3
Max. connectable cross-section: 1.5 mm
114
Technical specifications
Voltage:
3 AC 380 V -10 % (-15 % < 1 min) ... 3 AC 480 V +10 %
3 AC 500 V -10 % (-15 % < 1 min) ... 3 AC 690 V +10 %
Frequency: 47 ... 63 Hz
Connecting lugs:
Frame size HXL: d = 13 mm (M12/50 Nm) for cable lugs in accordance with DIN 46234 /
DIN 46235
1)
Frame size JXL: d = 13 mm (M12/50 Nm) for busbar connection
Voltage:
570 ... 720 V DC
750 ... 1035 V DC
Connecting lugs: d = 13 mm (M12/50 Nm) for busbar connection
Connecting lugs:
Frame size HXL: d = 13 mm (M12/50 Nm) for cable lugs in accordance with DIN 46234 /
DIN 46235
1)
Frame size JXL: d = 13 mm (M12/50 Nm) for busbar connection
Terminal strip X9
Terminal
Signal name
1
P24 V
1
P24 V
2
M
2
M
3
Bypass contactor control
4
5
Pre-charge contactor
control
6
7
EP +24 V (Enable Pulses) Supply voltage: 24 V DC (20.4 ... 28.8 V)
8
EP M1 (Enable Pulses)
Technical data
External 24 V DC supply
Voltage: 24 V DC (20.4 ... 28.8 V)
Current consumption: See Technical data
for Active Interface Module, -X609;11
for Active Interface Module,-X609;12
for Active Interface Module, -X609;9
for Active Interface Module, -X609;10
Current consumption: 10 mA
2
Water-cooled chassis power units for common cooling circuits
Manual, 08/2017, 6SL3097-4AM10-0BP0

Advertisement

Table of Contents
loading