Motor-side power components
7.2 Motor reactors
Table 7- 9
Technical data of motor reactors 500 V ... 690 V 3 AC, Part 1
Article number
Suitable for Motor Module
Type rating of the Motor Module
Rated current
Power loss
- at 50 Hz
- at 150 Hz
Connections
- To the Motor Module (1U1, 1V1, 1W1)
- Load (1U2, 1V2, 1W2)
- PE
Max. permissible cable length between
the motor reactor and motor
- without motor reactor
- for 1 motor reactor
- for 2 motor reactors in series
Degree of protection
Dimensions
Width
Height
Depth
Weight, approx.
192
6SL3000-
2AH31-0AA0
6SL3325-
1TG31-0AA3
kW
90
A
100
kW
0.269
kW
0.3
M10
M10
M6
m
m
m
IP00
mm
270
mm
248
mm
200
kg
25
2AH31-5AA0
2AH32-4AA0
1TG31-5AA3
1TG32-2AA3
132
150
0.296
0.332
M10
M10
M6
300 (shielded) / 450 (unshielded)
300 (shielded) / 450 (unshielded)
525 (shielded) / 787 (unshielded)
IP00
270
248
200
25.8
Water-cooled chassis power units for common cooling circuits
Manual, 08/2017, 6SL3097-4AM10-0BP0
2AH33-6AA0
1TG33-3AA3
200
315
215
330
0.376
0.4
0.425
0.454
M10
M10
M10
M10
M6
M6
IP00
IP00
300
300
285
285
212
212
34
46