Setting up drives
13.2 Setting up drives
General settings
Entry
Type
Connection
Device
Partition
Path
Access level
Softkey text
Softkey icon
Text file
Text context
User name
Password
416
Meaning
No drive
No drive defined.
USB local
Access to the USB memory medium is only realized via the
TCU to which it is connected.
USB drives are automatically identified if the memory medium
is inserted when the HMI powers-up.
USB global
All of the TCUs in the plant network can access the USB
memory medium.
- USB global is not possible under Windows!
NW Windows
Network drive
Local drive
Local drive
Front
USB interface that is located at the front of the operator panel.
X202
USB interfaces X202/X203 that are located at the rear of the
X203
operator panel.
Names of the TCU to which the USB memory device is
connected, e.g. tcu1. The NCU must already know the TCU
name.
Partition number on the USB memory medium, e.g. 1.
If a USB hub is used, specify the USB port of the hub.
Start direct directory of the data carrier that is connected
via the local drive.
Network path to a directory that has been released in the
network. This path must always start with "//", e.g.
//Server01/share3.
Assign access rights to the connections: From protection level
7 (key switch position 0) to protection level 1 (password:
Manufacturer).
The particular assigned protection level applies to all
operating areas.
Two lines are available as labeling text for the softkey. %n is
accepted as a line separator.
If the first line is too long, then it is automatically separated
into several lines.
If a blank is present, then this is used as line separator.
No icon
No icon is displayed on the softkey.
sk_usb_front.png
Icon file name
sk_local_drive.png
Icon file name
slpmdialog
File for softkey dependent on the language. If nothing is
specified in the input fields, the text appears on the softkey as
SlPmDialog
was specified in the input field "Softkey text".
If your own text files are saved, then the text ID, which is used
to search for the text file, is specified in the "Softkey text" input
field.
Enter the user name and the corresponding password for
which the directory is enabled on the server. The password is
displayed in encoded form as as string of "*" characters and is
stored in the "logdrive.ini" file.
. Is displayed on the softkey.
. Is displayed on the softkey.