Table 1-12: About Control Systems - NEC Storage M100 Series User Manual

Disk array unit
Hide thumbs Also See for Storage M100 Series:
Table of Contents

Advertisement

User Guide
3. When the snapshot function is used
If the snapshot function is used, updated information is copied from disk drives to the cache
memory when the disk array unit is started.
Because of this, the disk array unit's start up time is delayed by 10 seconds per 1 TB of the updated
information.
1.3.1.4 Power control systems without using power switches
1. Control Systems

Table 1-12: About Control Systems

switches.
Control system
ESMPRO/AC
(Works together with UPS)
ESMPRO/AC
(Automatic operation)
UPS
(Does not work with UPS)
Release 6.0
Control systems described here are supported only in the M300 series.
Table 1-12: About Control Systems
Host OS
Windows
Linux
Windows
Linux
Not specified
Association is a mechanism to notify the disk array system of interruption of power
supply to the UPS and to start shutdown.
If you use the UPS control system, establish redundancy by providing a UPS for
each power supply of a device.
Make sure that a failure of a single UPS does not cause simultaneous power failure
of PS0 and PS1.
describes power control systems that do not use power
Feature
This control system uses a server for power
control, which can be associated with hosts.
For details, see ESMPRO/AC manual.
This control system uses a server for power
control and allows for automatic operation.
For details, see ESMPRO/AC manual.
This control system is for instantaneous power
interruption.
Because there is no association, when the
retention period of UPS elapses, temporary
power-off followed by reboot takes place.
Cached data, however, is protected.
57
Chapter 1 Overview

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storage m300 series

Table of Contents