10.3.2 Errors in Initialization

Problem
Configuring any the following failed.
Setting disk array subsystem
name.
Setting the time (synchronization
with the NTP server)
Setting the time (manually)
Unlocking a license
Setting host connection port
(iSCSI)
Setting iSNS server
Setting host connection port (FC)
Port mode switching
Setting host connection port (SAS)
An error occurred in the completion
page of the initialization.
Whenever Storage Manager is
started, the dialog prompting to start
initialization is displayed.
Release 6.0
Cause and Solution
It is conceivable that a disk array problem or communication
error between the disk array and a client has occurred.
Check if the disk array or the client has a problem. Fix the
problem and then perform initialization again.
This problem may occur when the next generation Java
plug-in is not disabled.
See
Section 4.5.1: "Before Starting NEC Storage Manager
Client"
to disable the next generation Java plug-in, and then
perform the initialization again.
This problem occurs when initialization is not completed
successfully.
Start the initialization wizard and complete it successfully.