Settings Controlled By The Mechanical Controller, But Requiring Reading Out And Changing The Values - Epson AcuLaser C1900 Service Manual

A4 color page printer
Hide thumbs Also See for AcuLaser C1900:
Table of Contents

Advertisement

EPSON AcuLaser C1900/AcuLaser C900
1.4.5.4 Settings controlled by the mechanical controller, but
requiring reading out and changing the values
Table 1-46. Setting Item
Setting Item
Amount of C Toner used
Read-only, counter cleared when a new one is detected
Amount of M Toner used
Read-only, counter cleared when a new one is detected
Amount of Y Toner used
Read-only, counter cleared when a new one is detected
Amount of K Toner used
Read-only, counter cleared when a new one is detected
Life counter of C Toner
Read-only, counter cleared when a new one is detected
Life Counter of M Toner
Read-only, counter cleared when a new one is detected
Life Counter of Y Toner
Read-only, counter cleared when a new one is detected
Life Counter of K Toner
Read-only, counter cleared when a new one is detected
Amount of Photoconductor Unit used Read-only, counter cleared when a new one is detected
Amount of Transfer Belt used
Read-only, counter cleared when a new one is detected
Amount of Fuser Unit used
Clearing counter, read-only
Development bias adjustment
Changing a setting value (1 ~ 4), read-only
Normal paper second transfer voltage
Changing a setting value (-15 ~ 15), read-only
adjustment
Thick paper second transfer voltage
Changing a setting value (-15 ~ 15), read-only
adjustment
Transparency second transfer voltage
Changing a setting value (-15 ~ 15), read-only
adjustment
Envelope second transfer voltage
Changing a setting value (-15 ~ 15), read-only
adjustment
Postcard second transfer voltage
Changing a setting value (-15 ~ 15), read-only
adjustment
Back side of Thick paper second
Changing a setting value (-15 ~ 15), read-only
transfer voltage adjustment
Back side of Postcard second transfer
Changing a setting value (-15 ~ 15), read-only
voltage adjustment
Back side of Duplex second transfer
Changing a setting value (-15 ~ 15), read-only
voltage adjustment
Capacity of C Toner
Changing a setting value (1.5k, 4.5k), read-only
Capacity of M Toner
Changing a setting value (1.5k, 4.5k), read-only
Product Description
Outline of the operation
Control Panel
Table 1-46. Setting Item (continued)
Setting Item
Capacity of Y Toner
Changing a setting value (1.5k, 4.5k), read-only
Capacity of K Toner
Changing a setting value (1.5k, 4.5k), read-only
Mechanical control version
Read-only
Amount of C Toner used/Amount of M Toner used/Amount of Y Toner used/
Amount of K Toner used:
Indicate the consumption amount, from 0 to 100% (in 2% increment), expressed as
a counter value using the dot counter circuit. For the 1.5 k capacity toner, this
value is same as above.
Life counter of C Toner/Life Counter of M Toner/Life Counter of Y Toner/
Life Counter of K Toner:
The total number of printed pages after a new one is detected.
Amount of Photoconductor Unit used
Indicate the consumption amount of the photoconductor unit, from 0 to 100%
(in 2% increment).
Amount of Transfer Belt used
Indicate the consumption amount of the transfer belt, from 0 to 100%
(in 2% increment).
Amount of Fuser Unit used
Indicate the consumption amount of the fuser unit, from 0 to 100%
(in 2% increment).
NOTE: Since the fuser unit does not support the new unit detecting function, the
controller clears the counter.
Normal paper second transfer voltage adjustment
Adjust the second transfer voltage determined by the picture stabilization control
on normal papers.
Thick paper second transfer voltage adjustment
Adjust the second transfer voltage determined by the picture stabilization control
on thick papers.
Transparency second transfer voltage adjustment
Adjust the second transfer voltage determined by the picture stabilization control
on transparencies.
Revision B
Outline of the operation
64

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aculaser c900

Table of Contents