2.4.5.3 Transfer Belt Cleaner Mechanism

TRANSFER BELT CLEANER
The cleaning blade removes the residual toner on the transfer belt.
Cleaner Pressure Flapper Solenoid (SL4)
Cleaning Blade
Figure 2-18. Transfer Belt Cleaner Mechanism
Operating Principles
Belt Position Detection Sensor (PC5)
Cam
Cleaner Counter-roller
Description of Mechanisms
TRANSFER BELT CLEANER SEPARATION
The transfer belt cleaner is separated by turning on and off of the Cleaner Pressure Flapper
Solenoid (SL4) which activates rotation of the cam on the printer body.
(Driven by the main motor)
The cam driven on the printer body is brought into contact directly with the cleaner housing
to estrange the transfer belt cleaner. As the cam rotates and the belt cleaner position
detection sensor (PC9) is turned off, the transfer belt cleaner is detected to be separated.
Figure 2-19. Transfer Belt Cleaner Separation
Main Motor (M1)
ON
OFF
Belt Position Detection Sensor
Press
Cleaner Pressure
ON
Flapper Solenoid (SL4)
OFF
Revision B
Press
Estrange
*Color printing