EPSON AcuLaser C1900/AcuLaser C900
Withstand Voltage
Breakdown must not occur when the voltages shown in the table below are applied for
one minute.
Table 1-20. Withstand Voltage
For 100/120 V system models
For 220 V system models
Leak Current
100 V: 0.25 mA or less
*1
120 V: 3.5 mA or less
220 V: 3.5 mA or less
NOTE: *1: The measuring method is compliant with "PC-11-1988".
Product Description
Across primary and chassis
AC1,000 V
AC1,500 V
Basic Specifications

1.2.8 Compatible Standard

Safety Standard
100 V/120 V
UL1950 3rd Edition
CSA C22.2 No.950-95 3rd
200 V system
IEC60950 2nd + Amd 1, 2, 3, 4
EN60950: 2nd + Amd 1, 2, 3, 4, 11 (1997)
Annex ZB, ZC
Safety Standard (Laser Transmission)
120 V
FDA21CFR Chapter 1 Subchapter J Part1040
200 V system
EN60825-1 + A11
<Reference>
• Laser diode
Wavelength (Min. ~ Max.:)) 770 ~ 795 nm
Max. output rating:
EMI
100 V
VCCI Class B J55022 Class B
120 V
FCC 47CFR Part 15 Subpart B, Class B
CNS13483 Class B
ICES-003 Issue 3 Class B (C108.8-M1983)
200 V system
EN 55022 Class B
CISPR Publication22 Class B
Electrical higher harmonics wave
Complies with the Higher Harmonics Restraint Guidelines
100 V: Compliant with JBMG-3 (1995)
200 V: Compliant with EN61000-3-2 Class A
Electrical Power Consumption
Conforms to the International Energy Star Program standards
Revision B
5 mW