EPSON AcuLaser C1900/AcuLaser C900
4.5.20 Rack
1.
Remove the High Voltage Unit (HV). (p.188)
2.
Remove the HV Contact Assy. (3 screws)
3.
While supporting it with your hand, rotate the Rack to a position where you can see
through the cut area of the frame the screw securing a toner cartridge mounting frame
on the Rack.
4.
Remove the screws securing the toner cartridge mounting frame. (4 screws in total)
(See "Figure 4-58 (p.202)")
5.
Remove the Rack Fulcrum Cover. (2 screws)
6.
Separate the toner cartridge mounting frame from the Rack and take them out through
cut areas of the frame, respectively.
Figure 4-57. Removing the HV Thermal Assy
Disassembly and Assembly
(See "Figure 4-57 (p.202)")
(See "Figure 4-59 (p.202)")
(See "Figure (p.202)")
Printer Main Parts Disassembly and Assembly
Figure 4-58. Removing the Screws securing the Toner Cartridge Mounting Frame
Figure 4-59. Removing the Rack Fulcrum Cover
Revision B