Pvst+ In Multi-Vendor Networks; Pvst+ Extended System Id - Dell Force10 C150 Configuration Manual

Ftos configuration guide ftos 8.4.2.7 e-series terascale, c-series, s-series (s50/s25)
Hide thumbs Also See for Force10 C150:
Table of Contents

Advertisement

PVST+ in Multi-vendor Networks

Some non-Dell Force10 systems which have hybrid ports participating in PVST+ transmit two kinds of
BPDUs: an 802.1D BPDU and an untagged PVST+ BPDU.
Dell Force10 systems do not expect PVST+ BPDU (tagged or untagged) on an untagged port. If this
happens, FTOS places the port in error-disable state. This behavior might result in the network not
converging. To prevent FTOS from executing this action, use the command
err-disable cause invalid-pvst-bpdu
BPDU, the BPDU is dropped, and the port remains operational.

PVST+ Extended System ID

In
Figure
40-5, ports P1 and P2 are untagged members of different VLANs. These ports are untagged
because the hub is VLAN unaware. There is no data loop in the above scenario, however, PVST+ can be
employed to avoid potential mis-configurations.
If PVST+ is enabled on the Dell Force10 switch in this network, P1 and P2 receive BPDUs from each
other. Ordinarily, the Bridge ID in the frame matches the Root ID, a loop is detected, and the rules of
convergence require that P2 move to blocking state because it has the lowest port ID.
To keep both ports in forwarding state, use Extend System ID. Extend System ID augments the Bridge ID
with a VLAN ID to differentiate BPDUs on each VLAN so that PVST+ does not detect a loop, and both
ports can remain in forwarding state.
Figure 40-5. PVST+ with Extend System ID
Force10 System
. After you configure this command, if the port receives a PVST+
VLAN unaware
P1
untagged in VLAN 10
X
P2
untagged in VLAN 20
moves to blocking unless
Extended System ID is
enabled
Hub
no spanning-tree pvst
Per-VLAN Spanning Tree Plus | 845

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents