Figure 3-9
Note
Additional mounting options
For additional mounting options see FSS200 installation manual
3.8
Incorrect mounting
NOTICE
Incorrect mounting
The device can be damaged, destroyed, or its functionality impaired through improper
mounting.
• Before installing ensure there is no visible damage to the device.
• Mount the device using suitable tools. See operating instructions.
SITRANS FS130 & FS230
Compact Operating Instructions, 12/2023, A5E38755607-AF
Sensor clamping screw
Customer pipe
7ME39600*** Mounting Frame
Spring Clip (not present on some mounting
frame models)
Spacer bar
Reflect mount
3.8 Incorrect mounting
⑥
Spacer bar pin and reference hole
⑦
Mounting strap
⑧
Larger pipes may need additional mounting
straps
⑨
Orientation for Single path sensor at the 9
o'clock position
⑩
Orientation for Dual path sensor at the 10
and 2 o'clock positions
Installing/mounting