Installing/mounting
3.6 Installation Instructions
6. Carefully push display back into enclosure. Use a small screwdriver or blade to open the three
retaining clips within the transmitter when pushing the display back into place.
7. Remove O-ring from lid.
8. Reinstall display cover until mechanical stop. Wind back lid by one turn.
9. Mount O-ring by pulling it over the display cover and turn display cover until you feel friction
from the O-ring on both sides. Wind display cover further by one quarter of a turn to seal on
the O-ring.
10.Reinstall and tighten lid lock screw.
3.6.2

Wall mount enclosure

Opening lid
Care must be taken when opening the lid to avoid the lid falling.
Note
Mounting screws are not included
You will need four screws, able to support at least 25 kg (55 lbs).
28
CAUTION
Compact Operating Instructions, 12/2023, A5E38755607-AF