Panasonic VL-W1-N Series Setup And Maintenance Manual page 95

Laser welding machine
Table of Contents

Advertisement

No.
Name and description
Counter type to reset (SELECT 0 IN: ON)
w
Resets the trigger count and the error count for the selected file to "0".
Set D0 IN to specify the counter type to reset and turn ON SET IN (No.2).
Counter type to reset
both trigger count and error count
Error count
• It is not possible to reset only the trigger count.
14 to 19
RESERVE: System reservation
Do not connect externally.
20
SELECT 0 IN
21
SELECT 1 IN
22
SELECT 2 IN
With SELECT 0 IN to SELECT 2 IN, the setting target of D0 IN to D10 IN and Guide laser indication target
are specified.
• Select the setting target of D0 IN to D10 IN
Specify SELECT 0 IN to SELECT 2 IN corresponding to the setting target shown below. Keeping the input
of SELECT 0 IN to SELECT 2 IN and D0 IN to D10 IN (No.3 to 13), turn ON SET IN (No.2).
Setting target of D0 IN to D10 IN
File No.
Counter type to reset
• Select guide laser indication target
Specify SELECT 0 IN to SELECT 2 IN corresponding to the indication target of guide laser as shown
below. Keeping the input of SELECT 0 IN to SELECT 2 IN, turn ON GUIDE IN (No.26).
Indication by guide laser
Work distance
Scanning image
Working field
Masked data
23 to 25
RESERVE: System reservation
Do not connect externally.
26
GUIDE IN: Guide laser radiation input
The guide laser irradiates while this input is turned ON. (Up to 60 minutes)
Determine the guide laser radiation details by the combination of SELECT 0 IN to SELECT 2 IN (No. 20 to
No. 22). Keep the input state of SELECT 0 IN to SELECT 2 IN while GUIDE IN is turned ON.
This terminal is available when the DIP switch No. 2 is turned OFF.
Input this terminal with the shutter closed.
• Availability of the guide laser varies depending on LASER STOP 1A/1B IN, LASER STOP 2A/2B IN and INTERLOCK
state as follows.
When LASER STOP 1A/1B IN is open
When LASER STOP 2A/2B IN is open
When INTERLOCK terminals are open under non-remote control mode
When INTERLOCK terminals are open under remote control mode
27 to 35
RESERVE: System reservation
Do not connect externally.
SELECT 0
SELECT 0
I/O and INTERLOCK state
ME-VLW1N-SM-1
D0
OFF
ON
SELECT 1
OFF
OFF
ON
OFF
SELECT 1
OFF
OFF
ON
OFF
OFF
ON
ON
ON
SELECT 2
OFF
OFF
SELECT 2
OFF
OFF
OFF
OFF
Guide laser availability
Available
Not available
Available
Not available
95