Guide Laser Radiation Input - Panasonic VL-W1-N Series Setup And Maintenance Manual

Laser welding machine
Table of Contents

Advertisement

4-6-5 Guide laser radiation input

SHUTTER ENABLE IN (X11)
SHUTTER IN (X10)
SELECT 0-2 IN (No.20-22)
GUIDE IN (No.26)
READY OUT (Y6)
SHUTTER OPEN OUT (Y10)
SHUTTER CLOSE 1 OUT
SHUTTER CLOSE 2 OUT
Item
Time
T1
Around 200ms
to max. 1 sec.
T2
0 ms or more
T3
0.5 ms or more
T4
Max. 60 minutes
*1 : Select the indication contents of the guide laser with SELECT 0 IN to SELECT 2 IN as follows.
Indication by guide laser
Work distance
Scanning image
Working field
Masked data
*2 : Keep the input state of SELECT 0 IN to SELECT 2 IN (No.20-22) while GUIDE IN (No.26) is turned ON.
• Guide indication by I/O is available when the DIP switch No. 2 is turned to OFF.
• If inputting GUIDE IN (No.26) repeatedly, turn ON GUIDE IN at intervals of more than 500 ms.
• Guide laser cannot radiate in the following state.
• LASER STOP 2A/2B IN (X16, 17) in I/O terminal are opened.
• INTERLOCK terminals are opened at the remote mode.
116
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON (Open)
OFF (Close)
T1
ON (Close)
OFF (Open)
Remarks
SHUTTER OPEN OUT (Y10) and SHUTTER CLOSE 1&2 OUT (Shutter close output
terminal No.2, 3) have a delay time of up to one second from turning ON of SHUTTER IN
(X10) for the actual shutter open / close operation time.
SHUTTER OPEN OUT and SHUTTER CLOSE 1&2 OUT will be output by the same
operation, but their output timing has a margin of error.
Turn on GUIDE IN (No.26) with the shutter closed.
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN (No.20-22),
turn on GUIDE IN (No.26).
The guide laser is stopped automatically after passing 60 minutes from start-up.
SELECT 0 IN (No. 20)
OFF
ON
OFF
ON
ME-VLW1N-SM-1
*1
T3
T2
T1
SELECT 1 IN (No. 21)
OFF
OFF
ON
ON
*2
T4
T1
SELECT 2 IN (No. 22)
OFF
OFF
OFF
OFF

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Vl-w1500-nVl-w1a00-nVl-w1506-nVl-w1a06-n

Table of Contents