3.2

MES Interface Module

This section shows the function list of an MES interface module.
Function
Data input/output
Device memory input/output
function
function
DB input/output function
Variable input/output
function
External
Program execution function
communication
client function
Information linkage
Trigger condition monitoring
function
function
Job execution control
function
Trigger buffering function
One-shot execution function
Data operation and
processing function
Data linkage function
Communication test
function
DB information browse
*2
function
External
REST server function
communication
server function
Security function
User authentication function
Other functions
SD memory card
management function
Self-diagnostics function
Online module change
function
Firmware update function
Initialization function
*1 Array tag components can be substituted only for an RD81MES96N.
*2 Can be used only for an RD81MES96N.
Description
Device memory input
function
Device memory output
function
DB record input/output
function
DB buffering function
System variable input/
output function
User variable input/
output function
To execute a program on an application server via DB Connection Service.
To monitor values such as a time or device tag component, and start a job when a trigger condition
changes from false to true (the condition is satisfied).
To control job execution such as the availability of job execution depending on the number of jobs that
can be executed at the same time.
To buffer information required for job execution in a trigger buffer as trigger information.
To execute any job at any timing.
To perform the substitution
device tag component value.
Data assignment
function
To check the communication setting between an MES interface module and an access target device or
access target server.
To access a database according to a request from MES Interface Function Configuration Tool and
acquire a DB table name, DB field name, data type of a DB field, stored procedure name, and argument
information of a stored procedure.
To enable job-related operations and job information acquisition from an REST client.
In addition, the XML processing function of a MELSEC-Q series MES interface module is supported.
To prevent illegal access to an MES interface module by setting a user name and password.
To format an SD memory card.
To diagnose whether an MES interface module operates normally.
To replace a module with another without stopping a running system. For the procedure, refer to the
following:
MELSEC iQ-R Online Module Change Manual
*2
To update the firmware of an MES interface module.
For details, refer to the following:
MELSEC iQ-R Module Configuration Manual
*2
To initialize a firmware update-prohibited password retained in an MES interface module.
To read data in the device memory.
Data used for trigger judgment is read, and then data used for job is read.
To write data written to a device tag in a job to the device memory.
To read/write data in the database of the host information system.
To buffer data sent to the database and resend it after recovery when the
data cannot be linked due to the disconnection of the network between an
MES interface module and the database or failure of the database, etc.
To read/write data of a system variable storing the operating status of a
module such as the status of an MES interface module.
To read/write data from/to a user variable (local variable/global variable)
which can be registered arbitrarily.
• Local variables: Available in a same job
• Global variables: Available between jobs
*1
, basic arithmetic operations, remainder, and character string operation of a
To assign and link a device tag, DB data, and a variable which are read by
using the data input/output function.
3 FUNCTION LISTS
3.2 MES Interface Module
3
53

Advertisement

Table of Contents
loading

Table of Contents