PW 6xx7
Service mode (service level)
1
Service programs
1
Test manually

Table 100-48: Selection-Display Module

When the desired item has been selected via the multifunction selector, press
the OK button. The selected service program then starts immediately and can
be stopped when the Back button is pressed.
Frequency converter has the following subdivisions:
Service mode (service level)
1
Service programs
1
Test manually
4

Table 100-49: Frequency Converter

When the desired item has been selected via the multifunction selector, press
the OK button. The selected service program then starts immediately and can
be stopped when the Back button is pressed.
Multifunction module 1 has the following subdivisions (multifunction
modules 2 and 3 are similarly divided):
Selection-display module (control element)
Designation
Display
e.g., Please turn the
multifunction selector
Multifunction
and a symbol for turning
selector
either clockwise or
counterclockwise
Please press the start
Start button
button. Start button
OK.
Buzzer is active and
display of buzzer symbol
Buzzer
above a multifunction
button.
Remote start and
Remote start
"Contact open" or
"Contact closed" symbol
Frequency converter
Designation
Display
Operating hours, # of times
machine is switched on/off,
Operating data
energy consumption,
average temperature, max.
temperature, model
Short circuit, high/low
voltage, power interruption,
Fault counter
offset fault, overload,
temperature, high current,
tachogenerator fault
List of last 16 faults
Fault memory
registered
Time, Rhythm, Spin
Motor
speed, V/A values
Tachogenerator
95
Technical Information
Explanation
Testing of the multifunction selector
(multifunction selector) and the OK button.
Start button can be pressed to test itself and
illuminated switch surround.
When the multifunction button with the
buzzer symbol above it is pressed, Buzzer
is active is displayed and the buzzer
sounds.
Control registers state of remote start relay
contacts.
Explanation
Display of EFU 235 operational data
registered by frequency converter control.
Display of EFU 235 faults registered by
frequency converter control.
e.g., 1st fault: Voltage interruption 1h. This
means that the first fault was a voltage
interruption that lasted for 1 hour.
Display of control data transmitted to
motor by frequency converter control.
Tachogenerator signal state.