Figure 100-7: Speed/Time Diagram For Automatic Spin Setting; Table 100-17: Spin Phases 1 To 6 For Automatic Spin Profile; Table 100-18: Maximum Selectable Spin Speed For Different Models - Miele PW 6 7 Series Technical Information

Table of Contents

Advertisement

PW 6xx7

Figure 100-7: Speed/Time Diagram for Automatic Spin Setting

Ph1
Ph2
Ph3
Ph4
Ph5
Ph6
max.
Phase
Phase 1 (Ph1)
Phase 2 (Ph2)
Phase 3 (Ph3)
Phase 4 (Ph4)
Phase 5 (Ph5)
Phase 6 (Ph6)

Table 100-17: Spin Phases 1 to 6 for Automatic Spin Profile

Maximum selectable spin speed for different models:
Model
PW 6107
PW 6137
PW 6167
PW 6207

Table 100-18: Maximum Selectable Spin Speed for Different Models

For further details and setting options, see Section 100-4.4.
Phase 1, pre-extraction, time 1 min 0 s, rhythm "No", speed 500 rpm
Phase 2, loosening, time 1 min 0 s, rhythm "12/3", speed 30 rpm
Phase 3, initial spin, time 1 min 0 s, rhythm "No", speed 500 rpm
Phase 4, spin, time 3 min 0 s, rhythm "No", speed 850 rpm
Phase 5, final spin, time 3 min 0 s, rhythm "No", maximum permitted spin speed for
model
Phase 6, loosening, time 2 min 0 s, rhythm "12/3", speed 30 rpm
Maximum permitted spin speed selection; see also Table 100-18.
Time
Rhythm
1 min 0 s
No
1 min 0 s
12s on / 3 s off
1 min 0 s
No
3 min 0 s
No
3 min 0 s
No
2 min 0 s
12s on / 3 s off
Maximum spin speed
1200 rpm
1100 rpm
1150 rpm
1100 rpm
45
Technical Information
Speed [rpm]
500
30
500
850
Maximum permitted speed; see Table
100-18
30