Table 100-22: Block Programming - Miele PW 6 7 Series Technical Information

Table of Contents

Advertisement

PW 6xx7
No.
31
32
33
34
35

Table 100-22: Block Programming

1
With payment system operation, Yes must be programmed in the last block of the complete
program to provide a reset signal to the payment system indicating that the program has finished.
Program Step
Basic Options
Drain (route for
Drainage path
water extracted in
2
spin cycle)
Free spin
No
speed selection
Spin
No
Repeat
No
Block end
Yes
1
signal
77
Technical Information
Setting Options
Notes
No drainage takes place. If No is
selected, a spin speed > 70 rpm
No
cannot be set in the Spin
program segment. Spinning with
water is prevented.
Drain
Activation of the drain valve.
Drained water is transferred to
Reservoir
the water recycling (WRG) tank.
The control empties the water
recycling tank by opening the
Empty reservoir
water recycling intake (K6), drain
valve (AVauf) and water
recycling (WRGauf) valves.
Water is pumped into the water
Cleaning
recycling (WRG) tank and
returned to the machine.
Control carries out spin cycle
No
with spin speed programmed for
this table/block.
Machine spins with most recently
set spin speed selected by
Yes
operator before program start,
providing this is not greater than
speed programmed for this block.
No
No spin carried out.
Control carries out an automatic
spin with 6 phases based on:
Pre-spin, loosening with
redistribution, spin with
Automatic
increasing spin speeds 500 rpm,
850 rpm, final spin speed,
loosening. For details, see
Sections 100-2.9 and 100-4.4.
Programmer creates a spin cycle
with 6 phases. Each individual
phase is programmed with three
User-defined
settings for "Time", "Rhythm" and
"Speed". For details, see tables
in Section 100-4.4.
This block will not be repeated in
either associated program
No
segment (e.g., pre-wash, main
wash or rinse) or complete
program.
"n" can be selected from 1 to 9
"n" x block
inclusive. This block will then be
repeated n times in program area
to which it belongs.
"m" can be selected from 1 to 9
inclusive. All blocks that have
been carried out until now since
"m" x program
program start (including this
block) will be repeated m times,
i.e. program up to and including
this block will be repeated m
times.
Control does not provide a block-
No
end signal.
Provision of a block-end signal
Yes
for 0.5 s at Block end signal
output when drum is stationary.

Hide quick links: