Table 100-21: Internal Structure Of Program Header For A Profitronic M Washing Program - Miele PW 6 7 Series Technical Information

Table of Contents

Advertisement

PW 6xx7
Item # in
Table
16
17
18
Table 100-21: Internal Structure of Program Header for a Profitronic M Washing
Program
Block programming - Profitronic M washing control:
No.
0
1
Item Description
Peak load
Hot water control
Price
Program Step
Basic Options
Block name
20 blank spaces
Block activation
No
Options
Details
High load peaks in electrical systems can
result in particularly high energy costs.
With major installations, a peak-load cut-
out feature avoids these extra charges for
load peaks. A monitoring system
registers current consumption and when
this is too high, a cutout signal is
produced. Machine response: Heating is
switched off and program may possibly
be interrupted. When monitoring system
resets signal, wash program continues
automatically. This setting determines if
heating will be switched off by a peak-
Yes / No
load signal being received at the Peak
load input. Default setting: Yes. If control
registers that header of program in
operation permits peak-load cutout and
program is currently in a heating step
when a peak-load signal is received, then
heating is switched off, program is
stopped and display shows Prog.
stopped. Peak load cut-out. Program
will start again automatically. Control
also corrects program finish time. If a
heating stage is not operating, no
message is displayed. Peak-load cutout
does not have an overriding time control.
With Yes setting and water intake control
set to Automatic, water inlet valves are
operated in a certain way. If possible,
control will attempt to achieve target
wash temperature during first water
intake by operating cold- and hot- water
Yes / No
valves alternately. Without water intake
control set to Automatic, control opens
programmed valves until target
temperature is reached and then
switches to cold-water intake only.
Default setting: No.
Price of a wash program is set on models
No / 0.10; 0.20; ...
with a payment system. No charge or a
9999.90 in 0.10
price between 0.10 currency units to
steps
9999.90 currency units can be set.
Default setting: No.
Setting Options
All available
alphanumeric and
special
characters
No
Permanent
Block +
69
Technical Information
Notes
For naming block 1. Max. length
20 characters, e.g., Pre-wash
Program block will be skipped
before and during program.
Program block will always be
carried out during program.
Program block will only be carried
out when Block + button is
activated before program start or
during program before block
would be started; otherwise,
block will be skipped.