Servicing the Carbon
Canister
Checking the Air Filter for the
Carbon Canister
Service Interval: After the first 50 hours
Every 200 hours
Check the opening at the bottom of the air filter for the
carbon canister to ensure that it is clean and free of
debris and obstructions
Clean the air filter for the carbon canister with clean,
compressed air.
Figure 46
Located Beneath the Driver's Seat
1. Air-filter opening
(Figure
46).
Electrical System
Maintenance

Electrical System Safety

Disconnect the battery before repairing the
machine. Disconnect the negative terminal first
and the positive last. Connect the positive terminal
first and the negative last.
Charge the battery in an open, well-ventilated
area, away from sparks and flames. Unplug the
charger before connecting or disconnecting the
battery. Wear protective clothing and use insulated
tools.

Servicing the Battery

Battery voltage: 12 V with 300 A (cold-cranking) at
-18°C (0°F).
Always keep the battery clean and fully charged.
If the battery terminals are corroded, clean them
with a solution of 4 parts water and 1 part baking
soda.
Apply a light coating of grease to the battery
g034099
terminals to prevent corrosion.