TOLL RESTRICTION-3/6-DIGIT-PRI

T-41
TOLL RESTRICTION-3/6-DIGIT-PRI
1. General Description
This feature allows the system to be programmed to restrict outgoing ISDN calls according to specific area and/
or Central Office codes.
2. Operating Procedure
No manual operation is required.
3. Programming
STEP 1: ASYD - System Data 1, Index 75:
STEP 2: ARSC - Assign Route Restriction Classes. When these are assigned to stations, classes will
CHAPTER 5
Page 156
Revision 1.0
System Data 2, Index 1, bit 3: Does
bits 4 & 5: If TOLL DENIAL is required, assign these bits as data
determine whether or not a station will be allowed access to a specific route or specific
dialing sequence. Assign the following:
DAY/NIGHT: Day/Night Mode
D: Day Mode
N: Night Mode
TN:
Tenant Number
RT:
Route Number
RSC: Route Restriction Class
RRI:
Route Restriction Index
0-IC Restriction via Attendant Console/station
1-IC Restriction Direct Connection
2-OG Restriction via Attendant Console/station
3-OG Restriction Direct Connection
RES: Restriction Data
0-Connection is Restricted
1-Connection is Allowed
2-Connection is Toll Restricted
Should the following commands be developed for Day/
Night? 0/1: No/Yes. See DAY/NIGHT CLASS OF
SERVICE [D-15] for more details.
-Bit 0- Develop ARSC command for Day/Night?
-Bit 3- Develop ATDP command for Day/Night?
TOLL
RESTRICTION
CALLING-STATION [S-21]? 0/1: Yes/No.
"00". If TOLL DIVERSION is required, assign these bits
as "01".
bit 7: Does
TOLL
RESTRICTION
CALLING-SYSTEM [S-3]? 0/1: Yes/No.