NEC NEAX 2400 IPX Programming Manual page 142

Hide thumbs Also See for NEAX 2400 IPX:
Table of Contents

Advertisement

OUTGOING TRUNK QUEUING-DELUXE-PRI
3. Programming
STEP 1: ASYD - System Data 1, Index 68, bit 3: OG Trunk Queuing (On-Hook) Automatic Cancel
STEP 2: ANPD - Reserve a number level for OG Trunk (ON-HOOK) Queuing.
STEP 3: ASPA - Assign the access code for OG Trunk (ON-HOOK) Queuing.
STEP 4: ARTD - Assign the OG Trunk Queuing-Deluxe service for the OG route.
STEP 5: ASFC - Allow OG Trunk Queuing-Deluxe to the SFC of the station.
Note:
For Off-Hook Queuing, the following data is required as well as above.
SFI21 (Off-Hook OG Queuing)=1
CHAPTER 5
Page 124
Revision 1.0
Index 159:
System Data 2, Index 4, bit 0: Call Back and OG Trunk Queuing access code.
Note:
System Data 3, Index 3, bit 5: 3-Burst for Ringer Pattern 5
Index 7:
CI=N and B.
CI=B, SRV=SSC, SID=19 (To set)
CI=N, SRV=SSC, SID=20 (To Cancel)
CDN9 (TQ)=1
CDN41 (TDMQ)=1 (for Tandem Queuing)
SFI62 (OG Trunk Queuing-Deluxe)=1
0/1=Out/In Service
Assign the OG-Trunk Queuing Automatic Cancel Timer,
when System Data 1, Index 68, bit 3 is "1". (Default
data=30 min.)
0/1=Separate/Common
bit 1: Automatic Setting of OG Trunk Queuing
0/1=Not Required/Required.
For OG Trunk (ON HOOK) Queuing, bit 1=0
For Off Hook Queuing, bit 1=1
0/1=Not required/Required
Ringer Pattern 5 for this service.
NDA-24305