CXDI-80C Wireless
The CXDI-80C Wireless is a slim-line lightweight flat panel detector (FPD) which has no
cables for communication or power supply and which has other features as well that are
designed for optimum ease of use. It uses the IEEE 802.11n (2.4 GHz/5 GHz) standard and can
display images at higher speeds than existing products.
The size of this FPD is the same as a film cassette complying with the ISO4090 standard, and it
enables digital radiography using existing analog radiography equipment. It has a light weight
of about 2.3 kg including the battery, and it delivers excellent operability.
The FPD realizes high resolution with a pixel pitch of 125 µm and employs cesium iodide (CsI)
for the scintillator to achieve enhanced sensitivity.
The CXDI-80C Wireless maintains system compatibility with the CXDI-70C Wireless,
allowing both to be used side-by-side in the same environment. In addition, an existing
installation can be used as is with the CXDI-80C Wireless, thereby minimizing the costs
associated with adding the CXDI-80C Wireless.
CXDI system software
80C detector body No.
X-ray interface box body No.
AC/DC box body No.
* Intended uses and applications
Diagnosis, prevention and monitoring of the diseases of patients
Exposing patients to X-rays, detecting the X-rays passed through the bodies of the patients and
converting them into digital images which are then provided to the physicians for diagnosis
Anticipated usage environments: X-ray exposure rooms, wards in general, health screening
Anticipated users:
Parties expected to install unit:
Anticipated examinees:
* Precautions for use
No guarantees are given for the system in terms of risk management control in regard to
providing protection from blood and chemicals in operating theaters (water-proof performance)
or assuring safety and hygiene or when it is used together with cardiac defibrillators in ICUs and
other locations, used outdoors or used in applications oriented toward animals. Operation of the
product in such circumstances must be performed under the responsibility and assurances of SI
(System Integrator) after the operating ranges allowed by the product's specifications have been
fully understood and acknowledged.
1
1
.
.
O
O
v
v
e
e
r
r
v
v
i
i
e
e
w
w
CXDI Control Software NE supported:
With Ver.1.40 or later
CXDI Controller RF: With Ver.1.40 or later
100001 or later
100001 or later
100001 or later
vans
Radiologists, physicians
Sales companies or agents which have received specialized
training
Patients
- 1 -