Chapter 12. PROFINET Network Management
12.1.6 MIB-II System Group Values
Many of the items provided by the MIB-II System Group are implementation-specific. The
values that are returned for the PNC are described below.
228
Name
sysDescr
Text description of the device being managed. For example:
PROFINET IO-Controller, ICRXICTL000
sysObjectID
Uniquely identifies the kind of device being managed. The first part of the
value returned (1.3.6.1.4.1.24893) indicates that this is a GE Intelligent
Platforms device. The two numbers after that (1.5) indicate that it is a product
made for the Control Systems Business. The three numbers after that identify
(in order):
For the RXi PNC: 1.3.6.1.4.1.24893.1.5.1.2.1
sysContact
Nothing (empty string)
The Device Name assigned to the node. If the Device Name hasn't been
sysName
assigned yet, an empty string is returned.
sysLocation
Nothing (empty string)
sysServices
79 (0x4F)
This value indicates the PNC has Layers 1–4 (physical, datalink, network and
transport) and Layer 7 (application) functionality.
PACSystems* RXi Distributed IO Controller User Manual
Family: RXi = 1
Product: PACSystems RXi PNC = 2
Model: (specific to each Family/Product combination)
Value
GFK-2816F