Heat Dissipation
During Start
...........................................................................................................................................
During Run
QLxxB0023D ~ QLxxB0053D
QLxxB0076D ~ QLxxB0105D
QLxxB0145D ~ QLxxB0220D
QLxxB0255D ~ QLxxB0500D
QLxxB0580D ~ QLxxB1000D
QLxxX0255D ~ QLxxX1600D
Certification
C
.............................................................................................................................................................................. IEC 60947-4-2
CE
............................................................................................................................................................................. IEC 60947-4-2
RoHS
.................................................................................................................. Compliant with EU Directive 2002/95/EC
CCC (pending) ...............................................................................................................................................................
GOST (pending) ...................................................................................................................................
Marine (pending) ............................................
UL / C-UL (pending) ............................................................................................................................................................
QLxxB0023D ~ QLxxB0425D, QLxxX0255D ~ QLxxX1600D .................................................................. UL Listed
QLxxB0500D ~ QLxxB1000D .................................................................................................................... UL Recognised
* For UL certification additional requirements may apply, depending on the models. For details, see UL
Compliant Installation.
4.5

UL Compliant Installation

This section details additional requirements and configuration settings for the ASTAT XL soft starters to
be UL-compliant. See also UL Fuse Selection and Short Circuit Ratings on page 80.
4.5.1
Models QLxxB0023D ~ QLxxB0105D
There is no additional requirement for these models.
4.5.2
Models QLxxB0145D ~ QLxxB0220D
• Use with finger guard kit part no. 995-09452-00.
• Use the recommended pressure terminal/connector kit. See Terminal/Connector Kit on page 15 for
more information.
4.5.3
Models QLxxB0255D ~ QLxxB0425D
• Use with finger guard kit part no. 995-14791-00.
• Use the recommended pressure terminal/connector kit. See Terminal/Connector Kit on page 15 for
more information.
4.5.4
Models QLxxX0255D
• Use the recommended pressure terminal/connector kit. See Terminal/Connector Kit on page 15 for
more information.
4.5.5
Models QLxxX0360D ~ QLxxX1600D
• Configure the busbars for line / load terminals at opposite ends of the soft starter (i.e. Top In,
Bottom Out or Top Out, Bottom In).
• Use the recommended pressure terminal/connector kit. See Terminal/Connector Kit on page 15 for
more information.
4.5.6
Models QLxxB0500D ~ QLxxB1000D
These models are UL recognised components. Separate cable landing busbars may be required within
the electrical cabinet when terminating cables sized according to the National Wiring Code (NEC)
regulations.
14
ASTAT XL User Manual
.......................................................................................................
.......................................................................................................
.....................................................................................................
.....................................................................................................
.....................................................................................................
................................................................................
Lloyds Marine No 1 Specification, ABS: 2010 Steel Vessels Rules
DET-812
Fout! Stijl niet gedefinieerd.
4.5 watts per ampere
39 watts approx
51 watts approx
120 watts approx
140 watts approx
357 watts approx
4.5 watts per ampere approx
GB 14048.6
GOST R 50030.4.1-2002
UL 508*