Panasonic LP-RF Series Setup & Maintenance Manual page 24

Laser marker
Hide thumbs Also See for LP-RF Series:
Table of Contents

Advertisement

Item
Required time for laser pumping
Power voltage
Power consumption
(Consumption current) *10
Grounding method
Cooling
method
Controller
Operating ambient temperature *11,
*12
Ambient temperature for storage *11
Operating ambient humidity *11
Protection degree of head *13
Overvoltage category
Pollution degree
Use location
Fiber cable length
Installation
direction
Controller
Weight
Controller
Battery
(mounted in
Quantity
product)
*1: Average output power from the laser marker at delivery time with the maximum laser power setting.
*2: There is approx. +/-0.5mm deviation per product.
*3: The value shown here is the configuration range that can be input. The setting values that can keep the quality of
marking or processing vary depending on the setting details and the target materials.
*4: Depending on the setting data, the available scan speed might be limited.
*5: Some of the languages or character types are not supported by this laser marker. Characters written from right to left
such as Arabic or Hebrew, characters based on ligature such as Indian languages cannot be input.
*6: VEC is a graphic file format dedicated for the laser marker. To use AI or EPS files, convert them to VEC format with the
attached software "ExportVEC".
*7: Available when the optional network unit is installed to the controller.
*8: OS versions of which Microsoft has ended support are excluded.
*9: The frequency switches automatically.
*10: The typical value of the inrush current at startup is as follows: (Duration time is 10ms or less.)
At 220V AC: 64A
*11: Common to the controller and the head. No condensation or freezing shall be allowed. If there is a gap between the
stored temperature and operating temperature, make sure to have the product get used to the operating ambient
temperature gradually prior to use to prevent the dew condensation.
*12: If the laser power is corrected in system offset or other detailed settings, the allowed temperature is defined with the
corrected value.
*13: The controller is non-compliant with the ingress protection rating. The ingress protection characteristics of the head
are ensured only when the fiber unit, laser emission protection glass, cables and connector covers are installed
properly.
24
Head
Head
Head
Type
Model
Weight
Model
LP-RF200P
Approx. 7 seconds
180V to 264V AC (including ±10% voltage fluctuations)
Frequency: 50/60Hz *9
370VA or less (2.1A or less)
Direct earth for both the head and the controller
Natural air-cooling
Forced air-cooling
With laser power setting 46 or more : 0°C to +36°C
With laser power setting less than 46 : 0°C to +40°C
-10°C to +60°C
35 to 85%RH
IP64
2
Indoor; at an altitude of 1000 m or below
3.0 ± 0.2 m, Minimum bent radius 80 mm
In all directions
Vertically
Approx. 8.0kg
Approx. 37kg
Manganese dioxide lithium primary battery
AFPX-BATT (CR-2450)
1
Approx. 7.0g
ME-LPRF-SM-11

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Lp-rf200p