4-5-2 Connecting common terminals

Connect IN COM. 1 (X2) and OUT COM. 1 (Y2) respectively to the power supply for input and output.
For the I/O connector terminals, connect IN COM. 2 and OUT COM. 2 respectively to the power supply in the same
manner.
Use the internal power
IN COM. 1 (X2)
NPN connection
OUT COM. 1 (Y2)
IN COM. 1 (X2)
PNP connection
OUT COM. 1 (Y2)
• Do not short-circuit 24V OUT (X1, Y3) and 0V OUT (Y1, X3). Also, do not short-circuit IN COM. 1 (X2) and OUT COM. 1
(Y2, X12). Starting the laser marker with these terminals short-circuited will cause the laser marker to malfunction.
• Do not mix up with the external and internal power supplies.
• Do not mix the NPN and PNP connecting patterns.
• When using the internal power supply (X1, X3, Y1, Y3), the total current of the power supply for the external device and
the consumption current for the I/O control should be less than 300mA.
• If you control the laser marker by the external power such as PLC, do not connect anything to the internal power 24V
OUT (X1, Y3) or 0V OUT (X3, Y1) of the I/O terminal block. If a short bar is installed, remove it.
• IN COM. 1 and OUT COM. 1 of the I/O terminal block are independent from IN COM. 2 and OUT COM. 2 of the I/O
connector. If you use the I/O connector terminal, connect input common/output common of the I/O terminal block and the
I/O connector to power supply respectively.
„ To use the internal power (the I/O terminal block is not connected to an external control device)
NPN connection
24V OUT
Short-
IN COM. 1
circuited
I/O terminal block
• The dotted line indicates that the terminals are connected inside of the laser marker.
• When connecting the internal power supply to IN COM. 1 and OUT COM. 1, use the attached short bars.
„ To use the external power (connected to an external control device such as PLC)
NPN connection
0V
IN COM. 1
24V
External power
supply
102
-
24V OUT (X1)
-
0V OUT (Y1)
-
0V OUT (X3)
-
24V OUT (Y3)
0V OUT
X1
Y1
OUT COM. 1
X2
Y2
X3
Y3
X4
Y4
X5
Y5
X6
Y6
OUT COM. 1
X1
Y1
X2
Y2
X3
Y3
X4
Y4
X5
Y5
I/O terminal block
Use the external power
IN COM. 1 (X2)
OUT COM. 1 (Y2)
IN COM. 1 (X2)
OUT COM. 1 (Y2)
PNP connection
Short-
IN COM. 1
circuited
Short-
0V OUT
circuited
I/O terminal block
PNP connection
IN COM. 1
X1
X2
X3
X4
X5
I/O terminal block
ME-LPRF-SM-11
-
24V
-
0V
-
0V
-
24V
X1
Y1
OUT COM. 1
X2
Y2
24V OUT
X3
Y3
X4
Y4
X5
Y5
X6
Y6
0V
Y1
OUT COM. 1
Y2
24V
Y3
External
Y4
power supply
Y5
Short-
circuited