Numeric; Numerical Parameter Composition - Canon imageRUNNER 1750 Series Service Manual

Hide thumbs Also See for imageRUNNER 1750 Series:
Table of Contents

Advertisement

#NUMERIC

■ Numerical Parameter Composition

No.
Item
002
RTN transmission condition (1)
003
RTN transmission condition (2)
004
RTN transmission condition (3)
005
NCC pause time length (pre-ID code)
006
NCC pause time length (post-ID code)
Time from Right After Dialing by Auto-dialing to Start of
008
Communication
010
line condition identification time length
011
T.30T1 timer (for reception)
012 The maximum number of received lines
013
T.30 EOL timer
015
hooking detection time length
016
time length to first response at time of fax/tel switchover
017
pseudo RBT signal pattern ON time length
018
pseudo RBT signal pattern OFF time length (short)
019
pseudo RBT signal pattern OFF time length (long)
020
pseudo CI signal pattern ON time length
021
pseudo CI signal pattern OFF time length (short)
022
pseudo CI signal pattern OFF time length (long)
023
CNG detection level at time of fax/tel switchover
024
pseudo RBT transmission level at time of fax/tel switchover
025
Answering machine connection function signal detection time
027
preamble detection time length for V21 low-speed flag
051
Hooking detection threshold
053
Setting of DTMF call origination count at remote reception of fax
055
acquisition period of environmental log data
056
Display the type of soft counter 1
057
Display the type of soft counter 2
058
Display the type of soft counter 3
059
Display the type of soft counter 4
060
Display the type of soft counter 5
061
Display the type of soft counter 6
062
Communication termination timer at SMTP transmission protocol
level
063
Communication termination timer at SMTP reception protocol level
064
Communication termination timer at POP reception protocol level
065
Communication termination timer at FTP transmission protocol level 0 to 65535 sec
8
Service Mode > Details of Service Mode > #NUMERIC > Numerical Parameter Composition
Range of settings
1% to 99%
2 to 99 item
1 to 99 lines
1 to 60 sec
1 to 60 sec
1 to 65 sec
0 to 9999 (10 msec)
0 to 9999 (10 msec)
0 to 65535 (line)
* Unlimited in the case
of 0
500 to 3000 (10 msec)
0 to 999
0 to 9
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 7
10 to 20
0 to 20 (120/230V)
0 to 999
20 (x 10ms)
0 to 480 (60min)
(0: no data acquisition)
101 (Fixed)
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 65535 sec
0 to 65535 sec
0 to 65535 sec
8
Service Mode > Details of Service Mode > #NUMERIC > Numerical Parameter Composition
No.
Item
066
Communication termination timer from start to completion of the
transmission of SMTP transmission data
067
Communication termination timer from start to completion of the
reception of SMTP reception data
068
Communication termination timer from start to completion of the
reception of POP reception data
069
Communication termination timer from start to completion of the
transmission of FTP transmission data
074
e-RDS RGW port number
075
Interval of transmission for e-RDS 3rd party
8-16
Range of settings
0 to 65535 sec
0 to 65535 sec
0 to 65535 sec
0 to 65535 sec
1 to 65535
default: 443
1 to 168 (hours)
default: 24
T-8-28
8-16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner 1740 seriesImagerunner 1730 series