Mitsubishi Electric 800 Series Installation Manualline page 59

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Para-
Name
meter
IP filter address 4
1445
(Ethernet)
[E800-(SC)E]
IP filter address 2
range specification
1446
(Ethernet)
[E800-(SC)E]
IP filter address 3
range specification
1447
(Ethernet)
[E800-(SC)E]
IP filter address 4
range specification
1448
(Ethernet)
[E800-(SC)E]
Ethernet command
source selection IP
1449
address 1
[E800-(SC)E]
Ethernet command
source selection IP
1450
address 2
[E800-(SC)E]
Ethernet command
source selection IP
1451
address 3
[E800-(SC)E]
Ethernet command
source selection IP
1452
address 4
[E800-(SC)E]
Ethernet command
source selection IP
1453
address 3 range
specification
[E800-(SC)E]
Ethernet command
source selection IP
1454
address 4 range
specification
[E800-(SC)E]
Keepalive time
1455
[E800-(SC)E]
Network diagnosis
1456
selection
[E800-(SC)E]
Extended setting for
Ethernet signal loss
1457
detection function
selection
[E800-(SC)E]
Load characteristics
1480
measurement mode
Load characteristics
1481
load reference 1
Load characteristics
1482
load reference 2
Load characteristics
1483
load reference 3
Load characteristics
1484
load reference 4
Load characteristics
1485
load reference 5
Load characteristics
1486
maximum frequency
Load characteristics
1487
minimum frequency
Initial
Setting Range
*1
Value
0
0 to 255
9999
0 to 255, 9999
9999
0 to 255, 9999
9999
0 to 255, 9999
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
9999
0 to 255, 9999
9999
0 to 255, 9999
60 s
1 to 7200 s
9999
0 to 2, 9999
0 to 3, 8888,
9999
9999
0, 1 (2 to 5, 81
0
to 85)
0% to 400%,
9999
8888, 9999
0% to 400%,
9999
8888, 9999
0% to 400%,
9999
8888, 9999
0% to 400%,
9999
8888, 9999
0% to 400%,
9999
8888, 9999
Gr.1: 60 Hz
0 to 590 Hz
Gr.2: 50 Hz
6 Hz
0 to 590 Hz
Para-
Name
meter
Upper limit warning
1488
detection width
Lower limit warning
1489
detection width
Upper limit fault
1490
detection width
Lower limit fault
1491
detection width
Load status
detection signal
delay time / load
1492
reference
measurement
waiting time
1499
Parameter for manufacturer setting. Do not set.
Alphabet (calibration parameters, etc.)
Para-
Name
meter
C0
FM terminal
*5
calibration [E800-1]
(900)
AM terminal
C1
calibration
*5
(901)
[E800-4][E800-5]
Terminal 2 frequency
C2
setting bias
*5
(902)
frequency
C3
Terminal 2 frequency
*5
setting bias
(902)
Terminal 2 frequency
125
setting gain
*5
(903)
frequency
C4
Terminal 2 frequency
*5
setting gain
(903)
Terminal 4 frequency
C5
setting bias
*5
(904)
frequency
C6
Terminal 4 frequency
*5
setting bias
(904)
Terminal 4 frequency
126
setting gain
*5
(905)
frequency
C7
Terminal 4 frequency
*5
setting gain
(905)
Terminal 4 bias
C38
command (torque/
*5
(932)
magnetic flux)
C39
Terminal 4 bias
*5
(torque/magnetic flux)
(932)
Terminal 4 gain
C40
command (torque/
*5
(933)
magnetic flux)
Terminal 4 gain
C41
(torque/magnetic
*5
(933)
flux)
C42
PID display bias
*5
coefficient
(934)
C43
PID display bias
*5
analog value
(934)
PARAMETER LIST
Initial
Setting Range
*1
Value
0% to 400%,
20%
9999
0% to 400%,
20%
9999
0% to 400%,
9999
9999
0% to 400%,
9999
9999
1 s
0 to 60 s
Initial
Setting Range
*1
Value
0 Hz
0 to 590 Hz
0%
0% to 300%
Gr.1: 60 Hz
0 to 590 Hz
Gr.2: 50 Hz
100%
0% to 300%
0 Hz
0 to 590 Hz
20%
0% to 300%
Gr.1: 60 Hz
0 to 590 Hz
Gr.2: 50 Hz
100%
0% to 300%
0%
0% to 400%
0%
0% to 300%
150%
0% to 400%
100%
0% to 300%
9999
0 to 500, 9999
20%
0% to 300%
53