Mitsubishi Electric 800 Series Installation Manualline page 30

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

WIRING
Ethernet model
l Recommended cable gauge: 0.3 to 0.75 mm
Safety communication model
l Recommended cable gauge: 0.3 to 0.75 mm
2.4.2 Wiring method
l Power supply connection
For the control circuit wiring, strip off the sheath of a cable, and use it with a blade terminal. For a single wire, strip off the
sheath of the wire and apply directly. Insert the blade terminal or the single wire into a socket of the terminal.
(1) Strip off the sheath for the below length. If the length of the sheath peeled is too long, a short circuit may occur with
neighbouring wires. If the length is too short, wires might come off.
Wire the stripped cable after twisting it to prevent it from becoming loose. In addition, do not solder it.
24
2
S1 S2 PC DI0 DI1 SD
10
2
5
4
A
B
C
2
SX1 SX2 PC SD
SY1
SY2
10
2
5
4
A
B
C
Cable sheath stripping length
10mm
SO SOC
SC1
SC2

Advertisement