PARAMETER LIST
Parameter 300 to 399
Para-
Name
meter
*7
DO0 output selection
313
*7
DO1 output selection
314
*7
315
DO2 output selection
*7
316
DO3 output selection
*7
317
DO4 output selection
*7
DO5 output selection
318
*7
319
DO6 output selection
*7
RA1 output selection
320
*7
321
RA2 output selection
*7
322
RA3 output selection
Communication
338
operation command
source
Communication
339
speed command
source
Communication
340
startup mode
selection
Communication
342
EEPROM write
selection
Communication
343
error count [E800]
Communication
*8
349
reset selection
Encoder rotation
*4
359
direction
Speed feedback
*4
367
range
*4
Feedback gain
368
Number of encoder
*4
369
pulses
Overspeed detection
374
level
Faulty acceleration
375
rate detection level
Encoder signal loss
*4
376
detection enable/
disable selection
% setting reference
390
frequency
[E800-(SC)EPA]
46
Initial
Setting Range
*1
Value
0, 1, 3, 4, 7, 8,
9999
11 to 16, 20, 24
to 26, 30 to 36,
38 to 41, 44 to
48, 56, 57, 60 to
9999
64, 70, 80, 81,
84, 90 to 93, 95,
96, 98 to 101,
9999
103, 104, 107,
108, 111 to 116,
120, 124 to 126,
9999
130 to 136, 138
to 141, 144 to
148, 156, 157,
9999
160 to 164, 170,
180, 181, 184,
190 to 193, 195,
9999
196, 198, 199,
206, 211 to 213,
242 [E800-
(SC)E], 306,
9999
311 to 313, 342
[E800-(SC)E],
9999
0, 1, 3, 4, 7, 8,
0
11 to 16, 20, 24
to 26, 30 to 36,
38 to 41, 44 to
48, 56, 57, 60 to
1
64, 70, 80, 81,
84, 90, 91, 95,
96, 98, 99, 206,
211 to 213, 242
4
[E800-(SC)E],
9999
0
0, 1
0
0 to 2
[E800]
0
0, 1, 10
[E800-(SC)E]
10
0
0, 1
0
(0 to 999)
0
0, 1
101
100, 101
0 to 590 Hz,
9999
9999
1
0 to 100
1024
2 to 4096
0 to 590 Hz,
9999
9999
0 to 400 Hz,
9999
9999
0
0, 1
Gr.1: 60 Hz
1 to 590 Hz
Gr.2: —
Parameter 400 to 499
Para-
Name
meter
PLC function
414
operation selection
Inverter operation
415
lock mode setting
Command pulse
scaling factor
420
numerator
(electronic gear
numerator)
Command pulse
multiplication
421
denominator
(electronic gear
denominator)
422
Position control gain
Position feed
423
forward gain
Position feed
425
forward command
filter
426
In-position width
427
Excessive level error
Pulse monitor
430
selection
Default gateway
442
address 1 [E800-
(SC)E]
Default gateway
443
address 2 [E800-
(SC)E]
Default gateway
444
address 3 [E800-
(SC)E]
Default gateway
445
address 4 [E800-
(SC)E]
Model position
446
control gain
Second applied
450
motor
Second motor
451
control method
selection
Second motor
453
capacity
Number of second
454
motor poles
Second motor
455
excitation current
Initial
Setting Range
*1
Value
0
0 to 2, 11, 12
0
0, 1
1
1 to 32767
1
1 to 32767
-1
-1
0 to 150 s
10 s
0% to 100%
0%
0 s
0 to 5 s
0 to 32767
100 pulses
pulses
0 to 400k
40k pulses
pulses, 9999
0 to 5, 100 to
105, 1000 to
1005, 1100 to
9999
1105, 8888,
9999
0
0 to 255
-1
-1
0 to 150 s
25 s
[200/400 V class]
0, 3, 5, 6, 10, 13,
15, 16, 20, 23, 30,
33, 40, 43, 50, 53,
70, 73, 1800, 1803,
8090, 8093, 9090,
9999
9093, 9999
[575 V class]
0, 3, 5, 6, 10, 13,
15, 16, 30, 33,
8090, 8093, 9090,
9093, 9999
10 to 12, 20, 40,
9999
9999
0.1 to 30 kW,
9999
9999
2, 4, 6, 8, 10,
9999
12, 9999
9999
0 to 500 A, 9999

Advertisement