PARAMETER LIST
Para-
Name
meter
Torque control P
834
gain 2 (current loop
proportional gain)
Torque control
integral time 2
835
(current loop integral
time)
836
Torque setting filter 2
840
Torque bias selection
841
Torque bias 1
842
Torque bias 2
843
Torque bias 3
844
Torque bias filter
Torque bias operation
845
time
Torque bias balance
846
compensation
Fall-time torque bias
847
terminal 4 bias
Fall-time torque bias
848
terminal 4 gain
Analog input offset
849
adjustment
Brake operation
850
selection
853
Speed deviation time
854
Excitation ratio
Terminal 4 function
858
assignment
Torque current/Rated
859
PM motor current
Second motor torque
860
current/Rated PM
motor current
864
Torque detection
865
Low speed detection
Torque monitoring
866
reference
AM output filter
867
[E800-4][E800-5]
Speed detection
870
hysteresis
Input phase loss
872
protection selection
[3-phase]
*4
873
Speed limit
874
OLT level setting
Speed feed forward
control/model
877
adaptive speed
control selection
Speed feed forward
878
filter
Speed feed forward
879
torque limit
880
Load inertia ratio
Speed feed forward
881
gain
50
Initial
Setting Range
*1
Value
0% to 500%,
9999
9999
0 to 500 ms,
9999
9999
0 to 5 s, 9999
9999
9999
0 to 3, 9999
600% to 1400%,
9999
9999
600% to 1400%,
9999
9999
600% to 1400%,
9999
9999
9999
0 to 5 s, 9999
9999
0 to 5 s, 9999
0% to 100%,
9999
9999
0% to 400%,
9999
9999
0% to 400%,
9999
9999
100%
0% to 200%
0
0 to 2
1 s
0 to 100 s
100%
0% to 100%
0
0, 4, 6, 9999
9999
0 to 500 A, 9999
0 to 500 A, 9999
9999
150%
0% to 400%
1.5 Hz
0 to 590 Hz
150%
0% to 400%
0.01 s
0 to 5 s
0 Hz
0 to 15 Hz
1
0, 1
20 Hz
0 to 400 Hz
150%
0% to 400%
0 to 2
0
0.01 s
0.01 to 1 s
150%
0% to 400%
7 times
0 to 200 times
0%
0% to 1000%
Para-
Name
meter
Regeneration
882
avoidance operation
selection
Regeneration
883
avoidance operation
level
Regeneration
avoidance
885
compensation
frequency limit value
Regeneration
886
avoidance voltage
gain
888
Free parameter 1
889
Free parameter 2
Cumulative power
891
monitor digit shifted
times
892
Load factor
Energy saving
893
monitor reference
(motor capacity)
Control selection
during commercial
894
power-supply
operation
Power saving rate
895
reference value
896
Power unit cost
Power saving
897
monitor average time
Power saving
898
cumulative monitor
clear
Operation time rate
899
(estimated value)
Display safety fault
986
code [E800-SCE]
990
PU buzzer control
PU contrast
991
adjustment
Operation panel
setting dial push
992
monitor selection
[E800]
997
Fault initiation
PM parameter
998
initialization
Simple
Simple
Simple
Automatic parameter
999
setting
Simple
Simple
Simple
Parameter 1000 to 1099
Para-
Name
meter
Lq tuning target
1002
current adjustment
coefficient
1006
Clock (year)
Initial
Setting Range
*1
Value
0
0 to 2
[200 V class]
400 V
[400 V class]
300 to 1200 V
780 V
[575 V class]
944 V
0 to 45 Hz, 9999 6 Hz
0% to 200%
100%
0 to 9999
9999
9999
0 to 9999
9999
0 to 4, 9999
100%
30% to 150%
Inverter
rated
0.1 to 30 kW
capacity
0
0 to 3
0, 1, 9999
9999
9999
0 to 500, 9999
0 to 1000 h,
9999
9999
9999
0, 1, 10, 9999
0% to 100%,
9999
9999
0
0 to 127
1
0, 1
58
0 to 63
0 to 3, 5 to 14,
17 to 20, 23 to
33, 35, 38, 40 to
0
42, 44, 45, 50 to
57, 61, 62, 64,
65, 67, 91,
97, 100
9999
0 to 255, 9999
0, 8009, 8109,
0
9009, 9109,
10, 12, 20, 21,
9999
9999
Initial
Setting Range
*1
Value
50% to 150%,
9999
9999
2000
2000 to 2099