Mitsubishi Electric 800 Series Installation Manualline page 57

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Para-
Name
meter
1007
Clock (month, day)
1008
Clock (hour, minute)
Integral stop
1015
selection at limited
frequency
PTC thermistor
1016
protection detection
time
Trace operation
1020
selection
1022
Sampling cycle
Number of analog
1023
channels
1024
Sampling auto start
Trigger mode
1025
selection
Number of sampling
1026
before trigger
Analog source
1027
selection (1ch)
Analog source
1028
selection (2ch)
Analog source
1029
selection (3ch)
Analog source
1030
selection (4ch)
Analog source
1031
selection (5ch)
Analog source
1032
selection (6ch)
Analog source
1033
selection (7ch)
Analog source
1034
selection (8ch)
Analog trigger
1035
channel
Analog trigger
1036
operation selection
1037
Analog trigger level
Digital source
1038
selection (1ch)
Digital source
1039
selection (2ch)
Digital source
1040
selection (3ch)
Digital source
1041
selection (4ch)
Digital source
1042
selection (5ch)
Digital source
1043
selection (6ch)
Digital source
1044
selection (7ch)
Digital source
1045
selection (8ch)
Digital trigger
1046
channel
Digital trigger
1047
operation selection
Initial
Setting Range
*1
Value
Jan. 1 to
101
Dec. 31
0
0:00 to 23:59
0
0 to 2
0 s
0 to 60 s
0
0 to 3
1, 2, 5, 10, 50,
1
100, 500, 1000
1 to 8
4
0
0, 1
0
0 to 4
90%
0% to 100%
201
202
1 to 3, 5 to 14,
17 to 20, 23, 24,
203
32, 33, 35, 40 to
42, 52 to 54, 61,
62, 64, 65, 67,
204
83
[E800-(SC)EPA],
205
91, 97, 201 to
210, 212, 213,
222 to 227, 229
206
to 232, 235 to
238
207
208
1
1 to 8
0
0, 1
1000
600 to 1400
0
0
0
0
0 to 255
0
0
0
0
1
1 to 8
0
0, 1
Parameter 1100 to 1399
Para-
Name
meter
Deceleration time at
*3
1103
emergency stop
1106
Torque monitor filter
Running speed
1107
monitor filter
Excitation current
1108
monitor filter
Station number in
1124
inverter-to-inverter
link [E800-(SC)E]
Number of inverters
in inverter-to-inverter
1125
link system
[E800-(SC)E]
1150 to
PLC function user
parameters 1 to 50
1199
AM output offset
1200
calibration
[E800-4][E800-5]
First positioning
1222
acceleration time
First positioning
1223
deceleration time
First positioning
1225
subfunction
Second positioning
1226
acceleration time
Second positioning
1227
deceleration time
Second positioning
1229
subfunction
Third positioning
1230
acceleration time
Third positioning
1231
deceleration time
Third positioning
1233
subfunction
Fourth positioning
1234
acceleration time
Fourth positioning
1235
deceleration time
Fourth positioning
1237
subfunction
Fifth positioning
1238
acceleration time
Fifth positioning
1239
deceleration time
Fifth positioning
1241
subfunction
Sixth positioning
1242
acceleration time
Sixth positioning
1243
deceleration time
Sixth positioning
1245
subfunction
Seventh positioning
1246
acceleration time
Seventh positioning
1247
deceleration time
PARAMETER LIST
Initial
Setting Range
*1
Value
5 s
0 to 3600 s
9999
0 to 5 s, 9999
9999
0 to 5 s, 9999
9999
0 to 5 s, 9999
9999
0 to 5, 9999
2
2 to 6
0
0 to 65535
3000
2700 to 3300
5 s
0.01 to 360 s
5 s
0.01 to 360 s
0, 1, 10, 11,
10
100, 101, 110,
111
5 s
0.01 to 360 s
0.01 to 360 s
5 s
0, 1, 10, 11,
10
100, 101, 110,
111
0.01 to 360 s
5 s
5 s
0.01 to 360 s
0, 1, 10, 11,
10
100, 101, 110,
111
5 s
0.01 to 360 s
5 s
0.01 to 360 s
0, 1, 10, 11,
10
100, 101, 110,
111
5 s
0.01 to 360 s
5 s
0.01 to 360 s
0, 1, 10, 11,
10
100, 101, 110,
111
5 s
0.01 to 360 s
5 s
0.01 to 360 s
0, 1, 10, 11,
10
100, 101, 110,
111
5 s
0.01 to 360 s
0.01 to 360 s
5 s
51

Advertisement

Table of Contents
loading

Table of Contents