1-10. Installation Procedure
9. Set the air supply socket to the outside air supply tube, then connect the socket with the air supply
porthole of the air blow assembly.
n
Seal the air supply socket to the air supply porthole until the click can be heard.
When the outside air supply tube is 1/4 inch, it is possible to use the supplied air supply socket.
When the outside air supply tube is not 1/4 inch, use the air supply socket suitable to it.
Recommended socket : Nitto Industry Corporation, Hi-coupler socket (20 type, 30 type, 40 type)
Do not supply the outside air before completing the installation.
10. Insert the drain assembly to the drain (one-touch joint) of the air blow assembly.
w
Be sure to connect the tube with the drain.
If no tube is connected, there is a case that the liquid is scattered, then enters eyes or stains clothes.
When the liquid enters eyes, clean the eyes in the clean water immediately, then consult a physician.
n
. Unnecessary water and oil which are included in the supplied air is drained from the drain. To
receive it, take some measures (placing the saucer etc.).
. Insert the tube completely, then confirm that it is not come out by pulling slightly.
. Do not set the draining tube higher than the drain.
There is a possibility that the water and oil flows backward from the drain.
. The length of the tube should be 5 m or less.
Air supply porthole
Air supply socket
Outside air supply tube
1-12
Hi-coupler socket (through which the outside air is supplied) has the auto-
matic opening and shutting bulb, so when the socket is pulled out, the air
supply is stopped.
Air blow assembly
Drain
Draining tube (ø4)
FVS-1000 MMP1