Guidance and manufacturer's declaration ‐ electromagnetic immunity 
The GEMS‐H is intended for use in the electromagnetic environment specified below. The customer or the user of the GEMS‐H should 
assure that it is used in such an environment.
Immunity test 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Conducted RF 
3 Vrms 
IEC61000‐4‐6 
150 kHz to 80 MHz 
 
Outside ISM bands 
 
 
 
6 Vrms 
 
150 kHz to 80 MHz in ISM 
 
bands 
 
 
 
 
 
 
 
 
Radiated RF 
3 V/m 
IEC61000‐4‐3 
80 MHz to 2.7 GHz 
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies. 
NOTE  2:  These  guidelines  may  not  apply  in  all  situations;  Electromagnetic  propagation  is  affected  by  absorption  and  reflection  from 
structures, objects, and people. 
a  Field  strengths  from  fixed  transmitters,  such  as  base  stations  for  radio  (cellular/cordless)  telephones  and  land  mobile  radios,  amateur 
radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. 
To  assess  the  electromagnetic  environment  due  to  fixed  RF  transmitters,  an  electromagnetic  site  survey  should  be  considered.  If  the 
measured field strength in the location in which the GEMS‐H is used exceeds the applicable RF compliance level above, the GEMS‐H should 
be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or 
relocating the GEMS‐H. 
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. 
c The ISM (industrial, scientific and medical) bands between 150 kHz and 80 MHz are 6.765 MHz to 6.795 MHz; 13.553 MHz to 13.567 MHz: 
26.957 MHz to 27.283 MHz; and 40.66 MHz to 40.70 MHz. 
 
 
SAIT‐IFU‐GEMS‐H Rev.1.1 (2019‐11) 
 
IEC 60601 
Compliance level 
test level 
 
 
 
 
 
 
 
 
3 Vrms 
 
c
 
 
 
 
 
c
 
6 Vrms 
 
 
 
 
3 V/m 
 
Electromagnetic environment‐ guidance 
Portable  and  mobile  RF  communications  equipment 
should  be  used  no  closer  to  any  part  of  the  GEMS‐H, 
including  cable.  Then  the  recommended  separation 
distance calculated from the equation appliance to the 
frequency of the transmitter. 
 
Recommended separation distance 
d=1.2 �� 
 
 
 
 
 
 
 
 
 
 
IEC 60601‐1‐2:2014 
d=2.0 ��  80 MHz to 2.7 GHz 
 
Where  P  is  the  maximum  output  power  rating  of  the 
transmitter  in  watts  (W)  according  to  the  transmitter 
manufacturer  and  d  is  the  recommended  separation 
distance in meters (m). 
Field  strengths  from  fixed  RF  transmitters,  as 
determined by an electromagnetic site survey,
be  less  than  the  compliance  level  in  each  frequency 
b
range.
 
Interference  may  occur  in  the  vicinity  of  equipment 
marked with following symbol: 
 
a
 should 