Mitsubishi Electric MELSEC Q Series Handbook page 198

Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

7
REPLACEMENT OF PROGRAM
(c) Setting procedure
1) Data selection
• Set a drive/path for reading in GPPQ or GPPA format.
• Click the [Browse] button to set the system name and machine name of the project to be read.
• Check the checkbox of data to be selected by with the [Param+prog] button, [Select all] button,
or the mouse.
• Click the [Execute] button after making necessary settings.
2) Canceling data selection
• When canceling the selected data arbitrarily:
Clear the checkmark (P) in the checkbox with the mouse or space key.
• When canceling all the selected data:
Click the [Cancel all selection] button.
(d) Precautions for reading the other format files
A6GPP, SW0S-GPPA
format data
For data selection
GPPA format file
reading
Ladder return positions
For data selection
7
- 11
For AnS series
Read data with GX Developer after performing the corresponding format conversion with
GPPA.
For the operating methods, refer to the Type SW4IVD-GPPA(GPP) Operating Manual.
For device comment selection, you may only choose either comment 2 or comment 1.
Deletes the project data on GX Developer and read the other format file.
The area in excess of the program capacity is deleted when read.
When the file includes microcomputer programs edited with other than the SFC program
(e.g. SW0SRX-FNUP), they are lost.
For QnAS series
Returning places are different between GPPQ and GX Developer.
Because of this, if the total of return sources and return destinations exceeds 24 lines in a
single ladder block, the program is not displayed properly.
Corrective action: Add SM400 (normally on contact) to adjust the return positions.
For the device memory and file register, you may select only one data name for each
item.