SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Hardware Description
NOTE
Table 3-4 Power consumption and maximum frame size of boards
Board
Power Consumption
Control board (SCU)
l Static: 18.8 W
H801SCUB
l Maximum: 22 W
H802SCUB
l Static: 14 W
l Maximum: 17 W
H801SCUF
l Static: 22 W
l Maximum: 25 W
H801SCUH
l Static: 89 W
l Maximum: 111 W (Fully
l Maximum: 134 W (Fully
H801SCUL
l Static: 40.4 W
l Maximum: 42.1 W
H801SCUN
l Static: 41 W
l Maximum: 62 W
H802SCUN
l Static: 30 W
l Maximum: 50 W
H801SCUK
l Static: 30 W
l Maximum: 50 W
Issue 24 (2018-07-30)
l The power consumption of the board is tested in the following conditions:
l
Working voltage: -53.5 V DC.
l
Ambient temperature: 25 °C.
l
Static power consumption: All ports do not carry any loads. Specifically, users under POTS
ports hang up phones, xDSL ports are deactivated, and optical modules are not installed on
optical ports
l
Maximum power consumption: All ports fully carry loads. However, only 25% users under
POTS ports concurrently pick up phones and the feeding current is 20 mA.
l The board power consumption slightly varies with the power module configured for the board and
discreteness of components.
configured with 10GE service
board)
configured with 20GE service
board)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Maximum Frame Size
2052 bytes. After the jumbo frame function is
enabled, a maximum of 9216 bytes can be
supported.
2052 bytes. After the jumbo frame function is
enabled, a maximum of 9216 bytes can be
supported.
2052 bytes. After the jumbo frame function is
enabled, a maximum of 9216 bytes can be
supported.
2052 bytes. After the jumbo frame function is
enabled, a maximum of 9216 bytes can be
supported.
2052 bytes. After the jumbo frame function is
enabled, a maximum of 9216 bytes can be
supported.
2052 bytes. After the jumbo frame function is
enabled, a maximum of 9216 bytes can be
supported.
2052 bytes. After the jumbo frame function is
enabled, a maximum of 9216 bytes can be
supported.
2052 bytes. After the jumbo frame function is
enabled, a maximum of 9216 bytes can be
supported.