Figure 2-34 Power distribution principle of the MA5608T chassis
The MPWC power interface board leads two -48 V input to the backplane, and then the
backplane supplies power to each board.
The MPWC boards supports two -48 V DC input. If one input is off, the other supplies power
to the chassis can guarantee normal running of the system.
The MPWD power interface board supports the AC input. After AC/DC conversion, the
power is supplied to the system backplane at -48 V DC.
Two MPWE boards can be configured for dual-system hot backup. Each MPWC board
supports one -48 V DC input. If one MPWE board is off, the other supplies power to the
chassis can guarantee normal running of the system.

2.6.8 Heat Dissipation

This topic describes the ventilation of the MA5608T chassis.
The MA5608T chassis has a fan tray at the left to blow air for heat dissipation.
The airflow for the MA5608T chassis is as follows: The cool air flows to the chassis through
the left side, and then the fans blow the air to the right side of the chassis through the boards.
Finally, the air exits through the right side of the chassis.
the MA5608T chassis.
Figure 2-35 Ventilation of the MA5608T chassis
Issue 24 (2018-07-30)
MPWC
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Back
plane
Figure 2-35
2 Subrack and Chassis
Board
shows the ventilation of
140

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartax ma5603tSmartax ma5608t

Table of Contents