Mitsubishi Electric MELSEC-Q Series User Manual page 102

Loop control module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

3 SPECIFICATIONS
Address
(decimal (hexadecimal))
CH1
CH2
167 (A7
)
Approach range setting
H
Approach soak time setting
168 (A8
)
H
PID continuation flag
169 (A9
)
H
Cascade ON/OFF
176 (B0
)
H
Cascade gain
177 (B1
)
H
Cascade bias
178 (B2
)
H
Cascade monitor
179 (B3
)
H
Alert 1 mode setting
192 (C0
)
208 (D0
)
H
H
Alert 2 mode setting
193 (C1
)
209 (D1
)
H
H
Alert 3 mode setting
194 (C2
)
210 (D2
)
H
H
Alert 4 mode setting
195 (C3
)
211 (D3
)
H
H
196 (C4
)
212 (D4
)
Scaling value
H
H
197 (C5
)
213 (D5
)
Scaling range upper limit value
H
H
198 (C6
)
214 (D6
)
Scaling range lower limit value
H
H
199 (C7
)
215 (D7
)
Scaling width upper limit value
H
H
200 (C8
)
216 (D8
)
Scaling width lower limit value
H
H
201 (C9
)
217 (D9
)
Hold command
H
H
202 (CA
)
218 (DA
)
Command advancing
H
H
203 (CB
)
219 (DB
)
SV tracking setting
H
H
204 (CC
)
220 (DC
)
Forced output command
H
H
Forced output manipulated value
205 (CD
)
221 (DD
)
H
H
(MV)
256 (100
)
512 (200
)
Segment monitor
H
H
257 (101
)
513 (201
)
Segment remaining time
H
H
258 (102
)
514 (202
)
Execution times monitor
H
H
259 (103
)
515 (203
)
Pattern end output flag
H
H
260 (104
)
516 (204
)
End status flag
H
H
3 - 67
Item
*1: Reading data is always available regardless of the write conditions. The setting value of the item to
which "Setting mode" is given as the condition for writing data can be changed only in the setting mode.
Note that changing the value in the operation mode causes a write data error. In addition, it is necessary
to turn on Setting change command (YnB) to change the setting value.
Range
Thermocouples
0 to 100
( )
(
0.1 )
Micro voltage
1 to 100
(mV), voltage (V),
(
0.1%)
current input (mA)
0 to 32767 (
0.1s)
0:Stop, 1:Continue
0: OFF, 1: ON
-10000 to 10000 (
0.001)
-1000 to 1000 (
0.1%)
0 to 14
Refer to Section 3.5.46
-32768 to 32767
0: without command,
1: hold
0: without command,
1: advancing
0: Disable SV tracking
1: Enable SV tracking
0: Forced output not
commanded
1: Forced output commanded
-200 to 4200
(If a value in the range of
-32768 to -201 is set, the
analog output value becomes
0mA.)
MELSEC-Q
(From the previous page)
Write condition
Default
Setting
Always
Disabled
mode
1
0
0
0
1000
0
0
0
0
0
0
0
0
0
0
0
(To the next page)
*1
Reference
Section
3.5.37
Section
3.5.38
Section
3.5.39
Section
3.5.40
Section
3.5.41
Section
3.5.42
Section
3.5.43
Section
3.5.44
Section
3.5.45
Section
3.5.46
Section
3.5.47
Section
3.5.48
Section
3.5.49
Section
3.5.50
Section
3.5.51
Section
3.5.52
Section
3.5.53
Section
3.5.54
Section
3.5.55
Section
3.5.56
Section
3.5.57
3 - 67