REPLACEMENT OF MELSECNET (II) AND /B (PLC TO PLC NETWORK)
(h) MELSECNET/H network 1 normal station 1Ns1/network 2 control station 2Mp3 (Inter-link
data transfer of gateway station)
For data transfer between MELSECNET/H networks 1 and 2, change the setting of MELSECNET (II)
2 and 3-tier by:
• Transferring the data between networks 1 and 2 by the setting of "Interlink transmission
parameters" between gateway stations 1Ns1 and 2Mp3
LB/LW
1FFF
2
- 39
MELSECNET/H network 1
Normal station 1Ns1
0
1Mp3
100
2Mp3
180
1Ns1
2Ns1
200
2Ns2
280
1Ns2
37F
MELSECNET/H network 2
Control station 2Mp3
LB/LW
0
1Mp3
2Mp3
100
2Mp3
180
2Ns1
200
2Ns2
27F
1FFF
Inter-link data transfer from module 1 to 2
Inter-link data transfer from module 2 to 1