SETUP THE SYSTEM

After the system data programming in
low. (The two routers should already be working correctly.)
STEP1: Turn power switch of the Main Unit on.
STEP2: Confirm that the CPU in Main Unit is working, and turn power switch of the Remote Unit on.
– The communication between Main Unit and Remote Unit starts.
STEP3: Confirm that the system data has been copying from Main Unit to Remote Unit.
– After 30 seconds, the RUN LED on CPU blade at Remote Unit flashes at 30 IPM.
STEP4: Confirm that the system data is backed up in Flash ROM of CPU blade at Remote Unit.
– SYSD LED on the CPU blade turns on, and the data back up starts. (It takes two minutes to
back up the system data.)
STEP5: Confirm that Normal Mode operation starts.
– The CPU blade in the Remote Unit resets itself automatically, and starts Normal Mode oper-
ation.