REMOTE UNIT OVER IP LINK DOWN NOTICE ASSIGNMENT

When the Main Unit and Remote Unit are disconnected due to a fault occurrence, the link down can be
notified to the Multiline Terminals that are connected to both units.
To provide the link down notice with the Multiline Terminals, in addition to the programming of "Survival
Mode Assignment", do the following programming.
START
CM90
Assign the Event Occurrence Notice button to
the Multiline Terminals.
NOTE:
CM0B
Specify the start time to notify the link down to
the Multiline Terminal after the disconnection
between Main Unit and Remote Unit is detect-
ed.
NOTE:
CM9B
Assign the link down notice for the UNIT
(except Main Unit) to the Event Occurrence
Notice button.
END
DESCRIPTION
Assign this data only to the station
number of the Multiline Terminal
that the link down is notified.
Assign the shorter time than the time
for automatic changeover to surviv-
al mode assigned by CM0B
Y=1XX>80.
If the longer time is set, the link
down cannot be notified.
Chapter 3 REMOTE UNIT OVER IP FEATURES
REMOTE UNIT OVER IP LINK DOWN NOTICE ASSIGNMENT
Y=00
(1)
My Line No. +
(2)
F1600-F1663: Event Occurrence Notice
NONE : No data
Y=1XX (VOIP Port [1] + Unit No. [02-50])
(1)
82
(2)
00
01
RESET
99
NONE : 0-6 seconds (Unit02-04)
Y=0
(1)
XX ZZ
XX: 01-64: Event Occurrence Notice
ZZ : 02-50: Unit No. to be notified (except
(2)
0 : To notify
1 : Not notified
3-32
DATA
,
+ Key No.
button No. 01-64
: Not notify the link down
: 0-6 seconds (Unit02-04)
0-30 seconds (Unit05-50)
: 588-594 seconds
(Unit02-04)
2940-2970 seconds
(Unit05-50)
(6 seconds increments [Unit02-
04]/30 seconds increments
[Unit05-50])
0-30 seconds (Unit05-50)
button No.
Main Unit)